The table shows the 15 published common sizes. Values should be reviewed together with actual operating conditions and installation requirements.

Cross-sectionAWGConductor constructionConductor diameterInsulation thicknessFinished diameterRated currentMaximum currentDC resistanceRated voltage
0.035 mm²AWG327/0.080.24 mm0.15 mmØ0.50±0.05 mm0.22 A0.35 A525 Ω/km250V
0.05 mm²AWG3010/0.080.29 mm0.15 mmØ0.58±0.05 mm0.31 A0.50 A370 Ω/km250V
0.07 mm²AWG2814/0.080.35 mm0.15 mmØ0.66±0.05 mm0.43 A0.70 A260 Ω/km250V
0.10 mm²AWG2721/0.080.42 mm0.15 mmØ0.73±0.05 mm0.62 A1.00 A188 Ω/km250V
0.12 mm²AWG2624/0.080.45 mm0.15 mmØ0.76±0.05 mm0.75 A1.20 A165 Ω/km250V
0.15 mm²AWG2530/0.080.50 mm0.15 mmØ0.85±0.05 mm0.95 A1.50 A150 Ω/km250V
0.20 mm²AWG2442/0.080.60 mm0.15 mmØ0.96±0.05 mm1.30 A2.00 A90.4 Ω/km250V
0.30 mm²AWG2362/0.080.70 mm0.15 mmØ1.00±0.05 mm1.90 A3.00 A65.6 Ω/km250V
0.35 mm²AWG2275/0.080.80 mm0.15 mmØ1.15±0.05 mm2.20 A3.50 A53.1 Ω/km250V
0.50 mm²AWG20105/0.080.90 mm0.15 mmØ1.26±0.05 mm3.20 A5.00 A36 Ω/km250V
0.75 mm²AWG18150/0.081.00 mm0.15 mmØ1.50±0.05 mm4.80 A7.50 A22.7 Ω/km600V
1.0 mm²AWG17200/0.081.13 mm0.20 mmØ1.72±0.05 mm6.30 A10.0 A19 Ω/km600V
1.5 mm²AWG15300/0.081.60 mm0.20 mmØ2.10±0.05 mm9.20 A15.0 A11.7 Ω/km600V
2.0 mm²AWG14400/0.081.78 mm0.20 mmØ2.35±0.05 mm12.5 A20.0 A9.45 Ω/km600V
2.5 mm²AWG13500/0.082.05 mm0.20 mmØ2.47±0.05 mm15.0 A25.0 A7.42 Ω/km600V